Podsumowanie treści

Strona 1 - Owners Manual

[Revision: April 15, 1998, 0-215-006, ©Rytec Corporation]DigitalGatewayInstallation &Owners ManualModel DG1200®

Strona 2

4INPUTS TO THE DIGITAL GATEWAYAC INPUTS (Figure 3)NOTE: All AC inputs should be contact closure orsolid state connections only. RC networks,MOV's

Strona 3 - TABLE OF CONTENTS

5To reset the system and leave the door open:Activate the Stop input or push the Open Jog/Resetbutton on the Digital Gateway. The system will resetand

Strona 4

6DC INPUTS (Figure 4)A0500027DC InputsDC InputsFigure 4NOTE: All DC inputs should be contact closure orNPN open collector only. RC networks,MOV's

Strona 5

7TIMERS (Figure 5)CLOSE Backup TimerOPEN Backup TimerAuto CloseTimerA/A CloseDelay TimerA/A Close Delay Timer—ON/OFF ButtonA0500027Figure 5NOTE: The t

Strona 6

8AUTO CLOSE DELAY TIMERThis timer delays the closing of the door when it isopened by an Auto input activator (terminal 14) orfloor loop (terminal 30).

Strona 7 - HOW TO USE MANUAL

9ALARM CONDITIONSCOnnECt, MISSING CONNECTIONSThe Digital Gateway monitors the N.C. inputs uponpower-up. The alarm indicates one or more missingrequire

Strona 8 - INTRODUCTION

10CL = 0, CLOSE TIME EXCEEDEDThis alarm indicates that the close backup timer hastimed out before the door has fully closed and thedoor has not operat

Strona 9 - Indicates the Door Is on

11A0500027EdGEFigure 13NON-ALARM CONDITIONSHELLO, SAFE START-UPWhen power is applied to the Digital Gateway the doorwill not move regardless of the st

Strona 10 - A0500027

12LOC, IDLE STATEThis message will be displayed when input 24 isactivated, the door is fully closed (on the closed limitswitch) and the Digital Gatewa

Strona 11

13REPLACEMENTThe fused disconnect must be in the OFFposition and properly locked and taggedbefore performing the following proce-dure.If the Digital G

Strona 13 - Set for 2 Seconds

14PROGRAM 2, INPUT 24This input can be used to place the Digital Gatewayinto an inactive condition, operate the door manuallyor automatically or open

Strona 14 - START-UP PROCEDURES

15PROGRAM 4, PROGRAMMABLE OPTIONSThis program section allows you to change the Openand Close inputs to constant pressure/jog, set areverse delay timer

Strona 15

161. To enter into the programming mode press andhold both the Open and Close Backup Timebuttons for three seconds. The display will changeto three 0&

Strona 16 - CL = 0

176. For the remaining programs use the Select buttonto scroll through the options. Use the UP andDOWN arrow keys to set the time or option andthe Set

Strona 17

18WIRING SCHEMATICSFAST-SEAL—ONE-SPEED DIGITAL GATEWAY (E4200)111- POWER- AC CONTROL- DC CONTROL- FLOOR LOOPTERMINAL BLOCKSBLACKREDBLUEBEIGEGREEN/YELL

Strona 18

19FAST-FOLD—TWO-SPEED DIGITAL GATEWAY (E4100)A1500143NOTE: This schematic is for general infor-mation only. Due to varying require-ments for individua

Strona 19 - OPTIONAL PROGRAMS

20PREDADOOR—TWO-SPEED DIGITAL GATEWAY (E4900)WIRING SCHEMATICS—PREDADOOR—TWO-SPEED DIGITAL GATEWAY (E4900)A7500148NOTE: This schematic is for general

Strona 20

TABLE OF CONTENTSPAG EHOW TO USE MANUAL... 1INTRODUCTION ...

Strona 21 - SETTING THE PROGRAM OPTIONS

DC INPUTS ... 6Photoeye—Terminal 15 ...

Strona 22 - PrOG - 1

PAG EPROGRAM 2, INPUT 24 ... 14LOC Condition ...

Strona 23

This page intentionally left blank.

Strona 24 - WIRING SCHEMATICS

1HOW TO USE MANUALHOW TO USE MANUALThroughout this manual, the following key words areused to alert the reader of potential hazardoussituations, or si

Strona 25 - A1500143

2INTRODUCTIONINTRODUCTIONYour door control box is equipped with Rytec's DigitalGateway® which is a state of the art, solid statemicroprocessor-ba

Strona 26 - A7500148

3EXPLANATION OF DIGITAL GATEWAYCONTROLSTERMINAL STRIPThe Digital Gateway has plug-in terminal strips alongthe left side of the unit. The power, output

Komentarze do niniejszej Instrukcji